When it comes to ensuring operational safety and facilitating reliable maintenance in medium and high-voltage power distribution systems, a robust Indoor HV Isolation Switch is a fundamental component. Our product line is engineered to seamlessly integrate into comprehensive Indoor High Voltage Switchgear Equipment, providing a visible break point for complete electrical isolation. We offer specialized solutions for common voltage levels, including a dependable Indoor Electrical Disconnect Switch 11kV model for standard industrial applications, as well as a higher-rated Indoor Electrical Disconnect Switch 33kV for more demanding utility and infrastructure setups. Each switch is designed to meet stringent safety protocols, protecting both personnel and equipment during circuit de-energization and servicing operations.
The Indoor HV Safety Disconnect Switch represents a pinnacle of safety-focused engineering for enclosed electrical environments. Its primary function is to provide a secure, visible air gap isolation, ensuring that a section of the circuit is completely de-energized and safe for maintenance work. Constructed with high-grade, durable materials, it is built to withstand electrical, thermal, and mechanical stresses typical in indoor switchgear installations. The design prioritizes clear operational status indication and incorporates robust interlocking mechanisms to prevent accidental or incorrect operation, which is critical for maintaining overall system integrity and personnel safety. Ease of manual operation, consistent performance over thousands of cycles, and compliance with international electrical standards are hallmarks of this essential safety device.
Key Features & Specifications:
Technical Parameters Table
| Parameter | 11kV Model Specification | 33kV Model Specification |
|---|---|---|
| Rated Voltage (Ur) | 12 kV | 36 kV |
| Rated Frequency | 50/60 Hz | 50/60 Hz |
| Rated Normal Current (Ir) | 630 A, 1250 A, 2000 A | 630 A, 1250 A, 2000 A |
| Rated Short-Time Withstand Current (Ik) - 3s | 25 kA, 31.5 kA, 40 kA | 25 kA, 31.5 kA |
| Rated Peak Withstand Current (Ip) | 63 kA, 80 kA, 100 kA | 63 kA, 80 kA |
| Power Frequency Withstand Voltage (1 min) - to earth & across open gap | 42 kV / 48 kV | 70 kV / 80 kV |
| Impulse Withstand Voltage (1.2/50 µs) | 75 kV | 170 kV |
| Mechanical Endurance | 2000 operations minimum | 2000 operations minimum |
| Operating Mechanism | Manual, Rotary | Manual, Rotary |
| Standards Compliance | IEC 62271-102, IEEE C37.34, ANSI Standards | |