Every application has different switching duties, duty cycles and environmental conditions. SanGao matches the right device to each one.
Switching and protection equipment for utility networks, from primary substations down to distribution feeders.
Indoor and outdoor devices for new substations, retrofit projects and prefabricated switchgear assemblies.
Compact load break switches and earthing switches for ring main units in urban and rural distribution.
Solar farms and wind parks need reliable isolation and protection on both the collector and grid side.
Outdoor switchgear and surge arresters for electrified rail lines, substations and overhead contact systems.
Heavy-duty switching for steel mills, cement plants, chemical works and mining power distribution.
Medium voltage isolation and protection for high-rise buildings, campuses, hospitals and data centres.
Replacing ageing oil and SF6 equipment with modern, compact and environmentally friendlier alternatives.
Four typical scenarios, and the equipment combination we recommend for each.
In a 12–40.5kV substation, the circuit breaker carries the primary switching duty — clearing faults, energizing feeders and supporting busbar transfer. Earthing switches provide the visible safety point before maintenance work begins.
Ring main units and secondary distribution cabinets rely on load break switches for normal load switching, and on combined vacuum switch–fuse units for transformer feeder protection. Air-insulated designs are increasingly preferred where SF6 use is restricted.
Pole-mounted distribution lines depend on drop-out fuses and cut-outs for transformer protection, and on outdoor vacuum or SF6 breakers where automatic reclosing and remote operation are required. Arresters protect the line against lightning overvoltage.
Solar and wind plants need reliable isolation on collector circuits and transformer feeders, often with frequent switching duty. Industrial plants and mining operations require heavy-duty devices that tolerate dust, vibration and high ambient temperature.
A quick reference for engineers specifying SanGao devices.
| Application | Typical Voltage | Recommended Equipment | Installation |
|---|---|---|---|
| Primary Substation | 12–40.5kV | Indoor vacuum circuit breaker, handcart type VCB, earthing switch | Indoor |
| Ring Main Unit | 10–24kV | Load break switch, vacuum LBS + fuse combination, grounding switch | Indoor |
| Overhead Distribution | 10–35kV | Drop-out fuse, cut-out fuse, outdoor boundary VCB, surge arrester | Outdoor |
| Solar & Wind Plant | 12–40.5kV | Disconnector, isolation switch, zinc oxide arrester | Indoor / Outdoor |
| Railway Traction | 27.5kV / 40.5kV | Outdoor vacuum breaker, SF6 breaker, surge arrester | Outdoor |
| Industrial & Mining | 10–35kV | Indoor VCB, load break switch, high speed earthing switch | Indoor |
| Commercial Buildings | 10–24kV | Compact indoor VCB, isolation switch, earthing switch | Indoor |
| Grid Retrofit | 12–40.5kV | Air-insulated LBS, eco-friendly switchgear, compact VCB | Indoor / Outdoor |