In What Applications Are Earthing Switches Used?

2025-09-16

Earthing switches are critical components in power systems, designed to provide a direct path to ground for electrical equipment during maintenance or in case of faults. By safely discharging residual currents, they protect personnel and equipment from electric shock and ensure that maintenance can be carried out without unnecessary risk. In this article, we examine in depth where earthing switches are used, their detailed product parameters, and why SanGao has become a trusted choice for customers worldwide. Our factory continues to deliver solutions that align with strict international standards and the evolving demands of modern power networks.


High Voltage Earthing Switch



Core Applications of Earthing Switches

To understand in what applications earthing switches are used, it is essential to first recognize their role within the electrical distribution chain. These switches are applied in different scenarios:


1. High Voltage Substations: Used to ground busbars and equipment for safe inspection and maintenance.

2. Switchgear Panels: Installed in medium and high voltage switchgear systems to provide grounding when disconnectors or circuit breakers are open.

3. Cable Testing: Provide grounding for cables before high-voltage testing procedures.

4. Wind and Solar Farms: Ensure safe maintenance during periods of isolation.

5. Industrial Facilities: Protect workers in factories with heavy electrical loads when maintenance or upgrades are required.


Our products have been widely applied in each of these environments. SanGao earthing switches are known for their reliability, durability, and compliance with IEC standards, making them suitable across industries.



Product Specifications and Parameters

Our factory has developed a wide range of models to meet different grid requirements. Below is a sample specification table summarizing our standard Earthing Switch designs.


Model Rated Voltage (kV) Rated Current (A) Short-time Wihdstand Current (kA/1s) Peak Withstand Current (kA) Operating Mechanism Application Scope
SG-ES12 12 630 25 63 Manual Spring Medium voltage switchgear, cable earthing
SG-ES24 24 1250 31.5 80 Motorized or Manual Substation applications, industrial systems
SG-ES40.5 40.5 2000 40 100 Motorized High voltage substations, renewable energy
SG-ES72.5 72.5 3150 50 125 Motorized with Remote Control Large power plants, high-capacity substations


All models are designed to withstand harsh environments and undergo rigorous testing at our facility. Our earthing switches incorporate anti-corrosion coatings, precision bearings, and quick-operating mechanisms to ensure dependable operation even under frequent switching conditions.



Safety Features

Safety remains the central priority in the design of every earthing switch. Our engineering team integrates the following protective features:


1. Visible break indicators for clear verification of grounding position.

2. Mechanical interlocks that prevent incorrect operation with disconnectors or circuit breakers.

3. Arc-resistant materials for high-voltage insulation parts.

4. High mechanical endurance to withstand thousands of operations.


By ensuring that each unit performs consistently, our factory supports utilities and industries in reducing downtime and avoiding accidents. SanGao continues to be recognized for reliable quality and thoughtful design.



Installation and Maintenance Guidelines

Proper installation and maintenance extend the life of every Earthing Switch. Below are our key recommendations:


1. Always follow local electrical codes and safety standards when installing.

2. Ensure grounding connections are properly tightened and corrosion-free.

3. Test operating mechanisms periodically to confirm smooth functionality.

4. Lubricate moving parts annually to avoid stiffness and wear.

5. Perform insulation resistance checks during routine shutdowns.


Our factory provides detailed manuals with every shipment, and our support team offers technical assistance to customers worldwide. This service commitment reinforces why many global partners select SanGao as their preferred brand.



Advantages of Choosing SanGao Earthing Switch

SanGao earthing switches stand out because of three key strengths:


1. Design Expertise: With decades of manufacturing experience, our engineers deliver products that balance functionality with cost efficiency.

2. Custom Options: Our factory can customize rated voltage, current, and mechanisms to match project-specific requirements.

3. After-Sales Support: We ensure each customer receives comprehensive technical support, training, and spare parts supply.


Our track record demonstrates why SanGao has built strong partnerships with utilities, EPC contractors, and industrial customers worldwide.



FAQ Section

Q1: In what applications are earthing switches used?
A1: Earthing switches are applied in substations, switchgear, industrial plants, and renewable energy farms to provide safe grounding during inspection or maintenance. They protect workers by discharging residual charges and securing equipment against accidental energization.

Q2: In what applications are earthing switches used in renewable energy systems?
A2: In wind and solar power plants, earthing switches are essential during maintenance shutdowns. They ground circuits before technicians access equipment, preventing electrical hazards. Our factory has supplied models with motorized operation for remote control, supporting the unique needs of renewable energy projects.

Q3: In what applications are earthing switches used in industrial environments?
A3: Industrial facilities often operate heavy machinery and high-voltage distribution networks. Earthing switches are installed in switchgear panels to ground circuits before service, reducing risks of electrical accidents. Our customers rely on SanGao models for dependable performance even in demanding production settings.



Why Choose Us?

Understanding in what applications earthing switches are used helps operators, engineers, and safety managers make informed decisions when selecting protective equipment. From substations to industrial facilities and renewable energy farms, earthing switches remain indispensable for safe operation and maintenance. Our factory has dedicated years of expertise to developing models that align with strict global standards.


By choosing SanGao products, customers benefit from dependable protection, thoughtful engineering, and long-term reliability. For more details, technical support, or quotations, reach out to Zhejiang SanGao Electric Co., Ltd. Our team is ready to provide product data, customization options, and service solutions tailored to your projects.

X
We use cookies to offer you a better browsing experience, analyze site traffic and personalize content. By using this site, you agree to our use of cookies. Privacy Policy
Reject Accept